Instruction manual
KEW MEG
series
MODEL 3315・3316
Compact Insulation resistance tester with 4-range
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Instruction manual

Instruction manualKEW MEGseriesMODEL 3315・3316Compact Insulation resistance tester with 4-rangeKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.

Pagina 2 - Contents

―8―①Meter zero adjuster ②Test button③Scale plate ④Pointer⑤Insulation resistance scale ⑥AC voltage scale⑦"BATTERY-GOOD" range ⑧Power-on-indic

Pagina 3 - 1.Safety warnings

―9―5−1 Mechanical zero adjustmentWith the Range switch set to the OFF position and withoutpressing the Test button, turn the Zero adjuster with ascre

Pagina 4

―10―5−3 Battery voltage check(1) Set the Range switch to the BATT. CHECK position.(2) Press the Test button or Remote control switch.(3) If the meter

Pagina 5 - 2.Features

―11―AC voltage measurement (Mains disconnection check)The AC voltage measurement function is available on any ranges.DANGER¡Never make measurement on

Pagina 6 - 3.Specification

―12―6−2 Insulation resistance measurementBefore performing any insulation test, check the maximum voltage that may be applied to the circuit under te

Pagina 7

―13―(2) Connect Earth probe to the earth terminal of the circuit undertest. If the circuit is not earthed, connect Earth probe to anyappropriate c

Pagina 8

―14―<Auto discharge function>This function allows electric charges stored in the capacitance ofthe circuit under test to be automatically discha

Pagina 9 - Extension probe

―15―Output Voltage(V)Output Voltage(V)rangerangerangerangerangerangerangerangelnsulation Reslstance(MΩ)lnsulation Reslstance(MΩ)Nominal voltage0.05MΩ5

Pagina 10 - 4.Instrument layout

―16―6−5 Using Guard Terminal (only for MODEL3315)Shown below is an example of the insulation resistancemeasurement of an electric wire. If Line probe

Pagina 11 - 5.Preparation for measurement

―17―DANGERNever open the Battery cover during a measurement.WARNINGTo avoid possible electric shock, remove test leads beforeopening the Battery cove

Pagina 12 - 6.Measurement

Contents1.Safety warnings ……………………………………………………12.Features ……………………………………………………………33.Specification ………………………………………………………44.Instrument layout …………………………

Pagina 13

―18―8.Notes on Housing case and accessories8−1 Case lidCase lid can be fit under the Housing case while makingmeasurement.(1) Unhook and open the Case

Pagina 14

―19―Female  ScrewMale ScrewProdPickel ProdExtension ProdHexagonal Hole8−3 Test prods and replacement1. Types of Test prodsMODEL8072:Standard Test pro

Pagina 15

―20―8−4 Adaptors for the Earth cord and replacement1. AdaptorsMODEL7131:Safety alligator clipConnected to the Earth terminal of the Earthterminal bo

Pagina 16

―21―8−5 Cleaning Meter coverThis instrument is managed by our company's quality standardand is delivered in the best condition after passed thei

Pagina 17 - Lower limit of insulation

DISTRIBUTOR08-07 92-1645A

Pagina 18

―1―1.Safety warnings○This instrument has been designed, manufactured and testedaccording to IEC 61010-1: Safety requirements for ElectronicMeasuring

Pagina 19 - Install batteries in correct

DANGER¡Never make measurement on a circuit in which the electricalpotential exceeds AC/DC600V(Measurement CAT. III 600V).¡Do not attempt to make measu

Pagina 20

―3―2.FeaturesMODEL3315 and 3316 are four-range insulation resistance testersfor testing low-voltage installation below 600V.¡Designed to following saf

Pagina 21

―4―250V50MΩ1MΩ0.05∼20MΩ500V100MΩ2MΩ0.1∼50MΩ1000V2000MΩ50MΩ2∼1000MΩ50V10MΩ0.2MΩ0.01∼5MΩwithin ±5% of indicated valueMeasuring ranges other than above,

Pagina 22 - Flat test bar

―5―<Operating error>Operating error (B) is an error obtained under the nominal operatingconditions, and calculated with the intrinsic error

Pagina 23

―6―Temperature & humidity : 0℃ ∼ 40℃ (RH: 85% or less)range (no condensation)Storage temperature & : -20℃ ∼ +60℃ (RH: 75% or less)humidity ran

Pagina 24 - 08-07 92-1645A

―7―OptionalMODEL7115 Extension probeMODEL8016 Pickle type prodPickle type prodExtension probe