Kyoritsu 2009A Manual de usuario

Busca en linea o descarga Manual de usuario para Herramientas Kyoritsu 2009A. KYORITSU 2009A User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - KEW SNAP

KEW SNAPSERIESKEW SNAP 2009ADIGITAL CLAMP METERKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.INSTRUCTION MANUAL

Pagina 2 - Contents

―8―*Effective Value (RMS)Most alternating currents and voltages are expressed in effectivevalues, which are also referred to as RMS (Root-Mean-Square)

Pagina 3 - 1.Safety Warnings

―9―4.Instrument Layout①Transformer JawsPick up current flowing through the conductor.②Jaw TriggerOperates the transformer jaws. Press to open the Tran

Pagina 4

―10―Data HoldResistanceVoltageAmpereLow frequency inputDCA auto zeroPeak modeLow battery warningContinuity CheckNegative signACDCAverage modeWhen the

Pagina 5 - CAT.III

―11―⑧Terminal CoverSlides over V/Ω and COM Terminals to prevent access to them whenOUTPUT terminal is in use.⑨OUTPUT Terminal(For AC or DC current ran

Pagina 6 - 2.Features

―12―5.Preparation for Measurement5−1 Checking Battery Voltage①Set the function selector switch to any position other than "OFF". ②When the d

Pagina 7 - 3.Specifications

―13―6.Measurement6−1 DC Current MeasurementDANGER●Do not make measurement on a circuit above 1000VDC. This maycause shock hazard or damage to the inst

Pagina 8

―14―NOTE● During current measurement, keep the transformer jaws fullyclosed. Otherwise, accurate measurement cannot be made. Themaximum measurable con

Pagina 9

―15―①Set the function selector switch to the "∼A" position. “AC" shouldbe shown on the upper left corner of the display.②Press the trig

Pagina 10

―16―①Set the function selector switch to the " V" position. “DC" shouldbe shown on the upper left corner of the display.②Slide the term

Pagina 11 - 4.Instrument Layout

―17―③Connect the tip of the red and black test leads to the circuit under testand take the reading on the display.NOTE● When the voltage under test me

Pagina 12

Contents1.Safety Warnings ……………………………………………………… 12.Features ……………………………………………………………… 43.Specifications ………………………………………………………… 54.Instrument Layout ………

Pagina 13

―18―6−6 Continuity Check (400Ω range fixed)※The continuity check mode is enabled by pressing the mode selectorswitch on resistance range. " &qu

Pagina 14 - 5.Preparation for Measurement

―19―DANGER●Never use the instrument on a high voltage circuit above 750VAC.This may cause electrical shock hazard and damage to theinstrument or the c

Pagina 15 - 6.Measurement

―20―DANGER●Never use the instrument on a circuit above 750VAC/1000VDC.This may cause electrical shock hazard and damage to theinstrument or the circui

Pagina 16 - 6−2 AC Current Measurement

―21―NOTE● In the PEAK mode, the auto-ranging feature is disabled andmeasuring ranges are fixed as follows.DC/ACA: 0-400.0ADC/ACV: 0-400.0A● The Sleep

Pagina 17 - 6−3 DC Voltage Measurement

―22―7−1 Sleep FunctionCAUTION●The instrument consumes small amount of battery power in thesleep mode. Make sure to set the function selector switch t

Pagina 18 - 6−4 AC Voltage Measurements

―23―NOTE● If the instrument in the Data Hold mode goes into "sleep," it willreturn to the normal mode.7−3 LoHz FunctionIn ACV or ACA range,

Pagina 19 - 6−5 Resistance Measurement

―24―②Slide the terminal cover to the right to disclose the OUTPUT terminaland insert the output plug into the terminal. Make connection to therecordi

Pagina 20 - 6−7 Frequency Measurement

―25―● Consult the output voltage specifications shown in section 3 andadjust the sensitivity of the recording device. ● For long hours of use of the O

Pagina 21 - 6−8 Peak Measurement

―26―WARNING●To avoid electric shock hazard, make sure to set the function selectorswitch to "OFF" and remove the test leads from the instrum

Pagina 22 - Peak Hold

―27―9.Optional Accessories● MODEL 8008 (For AC current measurement only)Multi-Tran Model 8008 is designed to increase the measuringcapability of a cla

Pagina 23 - 6−9 Average Measurement

―1―1.Safety Warnings○This instrument has been designed and tested according to IECPublication 61010: Safety Requirements for Electronic MeasuringAppar

Pagina 26

DISTRIBUTOR92―1394C06-05Kyoritsu reserves the rights to change specifications ordesigns described in this manual without notice and withoutobligations

Pagina 27

―2―Following symbols are used on the instrument and in the instructionmanual. Attention should be paid to each symbol to ensure your safety. Refer

Pagina 28 - 8.Battery Replacement

―3―CAUTION●Make sure that the function selector switch is set to an appropriateposition before making measurement. ●Always make sure to insert each pl

Pagina 29 - 9.Optional Accessories

―4―●Tear-drop-shaped jaws for ease of use in crowded cable areas andother tight places.●Accurate true-RMS reading of AC current or voltage with distor

Pagina 30

―5―3.SpecificationsMeasuring Ranges and Accuracy (at 23±5℃, 45-75% relative humidity)DC Current AAuto-ranging (Defaults to Lo):Lo:0-399.9A (Shifts to

Pagina 31

―6―AC Voltage ∼V (Crest factor(CF): 3.0 or less, peak voltage: 1200V or less)Auto-ranging (Defaults to Lo): Lo:0-39.99V (Shifts to Mid at 40.00V)Mid:1

Pagina 32 - DISTRIBUTOR

―7―●Operating System Dual Integration●Display Liquid crystal display with a maximumcount of 4000 plus annunciators●Overrange Indication "OL"