Kyoritsu 6315 Instruction Manual Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Herramientas Kyoritsu 6315 Instruction Manual. KYORITSU 6315 Instruction Manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 163
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - KEW6315

Instruction ManualInstruction ManualInstruction ManualInstruction Manual Power Quality Analyzer KEW6315

Pagina 2

KEW6315 Safety warnings KEW6315 - 8 - Safety warnings This instrument has been designed, manufactured and tested according to IEC 61010-1: Safe

Pagina 3 - - 1 - KEW6315

KEW6315 Displaying Trend graph KEW6315 - 98 - The following example shows 1P3W-2 (Single-phase 3-wire, 2-system). ”Change the items

Pagina 4 - KEW6315 - 2

Changing displayed items and display position KEW6315 - 99 - KEW6315 Changing displayed items and display position The displayed

Pagina 5 - - 3 - KEW6315

KEW6315 6.2 Integration value “Wh” KEW6315 - 100 - 6.2 Integration value “Wh” Press the Key. Display the screen for “Wh”: Integration val

Pagina 6 - KEW6315 - 4

6.2 Integration value “Wh” KEW6315 - 101 - KEW6315 e.g.) 1P3W-2 (Single-phase Three-wire, 2-system) “Change the displayed systems”

Pagina 7 - Unpacking procedure

KEW6315 6.3 Demand KEW6315 - 102 - 6.3 ”Demand” Press the Key. Display the screen for demand value. Change the screens to display the

Pagina 8

Shifts in specific period - Shifts in specific period Items displayed on the LCDRemaining time (time left) Demand in

Pagina 9

KEW6315 Demand change KEW6315 - 104 - Demand change Press the Key to move the cursor and to scroll the graph to right and left. Th

Pagina 10 - Safety warnings

6.4 Vector KEW6315 - 105 - KEW6315 6.4 Vector Press the Key. e.g.) 3P4W *1 For 3P3W3A, rms line voltages are displayed. *2 Phase a

Pagina 11 - DANGER

KEW6315 6.4 Vector KEW6315 - 106 - e.g.) Vector of 3P4W: ”V x desired magnification” : toggle the line lengths of voltage vector.

Pagina 12 - Caution

6.5 Waveform KEW6315 - 107 - KEW6315 6.5 Waveform Press the Key. e.g.) Waveform of 1P3W-2 (Single-phase 3-wire, 2-system): Vol

Pagina 13 - Chap. 1 Instrument overview

Safety warnings KEW6315 - 9 - KEW6315 DANGER  The instrument is to be used only in its intended applications or conditions. Ot

Pagina 14

KEW6315 6.6 harmonics KEW6315 - 108 - ”A x desired magnification” : toggle the magnifications of current waveform (vertical). 0.1 0.5 1

Pagina 15 - 1.2 Features

Displaying harmonics on the bar graph - Bar graph display e.g.) “Linearity” is displayed in “Full-scale”. In the above example, “Linea

Pagina 16

KEW6315 KEW6315 - 110 e.g.) 3P4W (Three-phase 4-wire) : with “LOG” and Items displayed on the graphExceeding the axis value Displaye

Pagina 17 - 1.4 Steps for measurement

Displaying harmonics on the bar graph KEW6315 - 111 - KEW6315 “Change the displayed chs” Press the Key to change the displayed

Pagina 18 - Chap.2 Instrument layout

KEW6315 Displaying the list of harmonics KEW6315 - 112 - Displaying the list of harmonics Press the (List) Key to display the list of harmoni

Pagina 19 - 2.2 Connector

Displaying the list of harmonics KEW6315 - 113 - KEW6315 ”Change the displayed harmonics orders” Press the Key to scroll the p

Pagina 20

KEW6315 6.7 Power quality KEW6315 - 114 - 6.7 Power quality Press the Key to display Power quality screen. Factors impair power quality and

Pagina 21

Factors impair power quality and symptoms KEW6315 - 115 - KEW6315 Power quality Waveform Symptom Adverse effect Transient, Over-voltage (imp

Pagina 22 - 3 Basic operations

KEW6315 Displaying recorded events KEW6315 - 116 - Displaying recorded events Press the (Event) Key to display the list of the recorded event

Pagina 23 - 3.2 Icons on the LCD

Displaying recorded events KEW6315 - 117 - KEW6315 Measurement of Swell/ Dip/ INT/ Inrush current Each event will be detected with the r.m.s.

Pagina 24 - 3.3 Symbols on the LCD

KEW6315 Safety warnings KEW6315 - 10 -  Never disconnect sensors from the connectors of the instrument while the instrument is in use.  Conne

Pagina 25 - Inst/ Integration/ Demand

KEW6315 Displaying recorded events KEW6315 - 118 - Detection of Transient Voltage waveforms will be monitored at approx 40ksps, gapless, to calc

Pagina 26 - Waveform

Displaying recorded events KEW6315 - 119 - KEW6315 ”Change the displayed area” Press the Key to scroll the page vertically. “

Pagina 27 - Harmonics

KEW6315 Displaying measured flicker values in list form KEW6315 - 120 - Displaying measured flicker values in list form Press the (Flicker) K

Pagina 28 - Settings

Displaying trend graph of Pst, 1min KEW6315 - 121 - KEW6315 Displaying trend graph of Pst, 1min The “Pst, 1min” measured in the rec

Pagina 29 - 4 Getting started

KEW6315 Displaying changes of Plt KEW6315 - 122 - Displaying changes of Plt Press the Key to move the cursor or to scroll the p

Pagina 30

Chap. 7 Other functions KEW6315 - 123 - KEW6315 Chap. 7 Other functions “Data hold” Display update can be disabled by pressing the “DATA HOLD”

Pagina 31 - Battery

KEW6315 Chap. 7 Other functions KEW6315 - 124 - “Auto-ranging” (Current range) Current ranges of each sensor are automatically switched accordin

Pagina 32

8.1 Data transfer to PC KEW6315 - 125 - KEW6315 Chap. 8 Device connection 8.1 Data transfer to PC Data in the SD card or the internal memor

Pagina 33 - Power cord connection

KEW6315 8.2 Using Bluetooth® function KEW6315 126 8.2 Using Bluetooth® function Measuring data can be checked on android devices in real-time v

Pagina 34

Connection to input/ output terminals KEW6315 127 KEW6315 1 Open the Connector cover. 2 Press the rectangular protrusion above a ter

Pagina 35

1.1 Functional overview -Inst/ Integration/ Demand Display the avg/ max/ min instantaneous values of voltage/ active power/ apparent power/ react

Pagina 36

KEW6315 8.4 Getting power from measured lines KEW6315 - 128 - 8.4 Getting power from measured lines If it is difficult to get power from an out

Pagina 37 - WARNING

Chap. 9 PC software for setting and data analysis KEW6315 - 129 - KEW6315 Chap. 9 PC software for setting and data analysis The special softwa

Pagina 38

KEW6315 10.1 Safety requirements KEW6315 - 130 - Chap. 10 Specification 10.1 Safety requirements Location for use : In door use, Altitude up to

Pagina 39 - Start of recording

10.2 General specification KEW6315 - 131 - KEW6315 Backlight (Press the LCD Key to turn off, press any key other than “Power” to turn on.) P

Pagina 40 - End of recording

KEW6315 10.2 General specification KEW6315 - 132 - Real-time OS : This Product uses the Source Code of T-Kernel under T-License granted by the

Pagina 41 - Start measurement

10.2 General specification KEW6315 - 133 - KEW6315 Data storage location : Internal FLASH memory Storage capacity 4MB (Data storage capacity

Pagina 42

KEW6315 Items measured at Instantaneous measurement KEW6315 - 134 - Items measured at Instantaneous measurement Frequency f [Hz] Displayed digit

Pagina 43 - (2) Wiring system

Items measured at Instantaneous measurement KEW6315 - 135 - KEW6315 R.M.S. Current A [Arms] Range MODEL8128 (50A) :5000m/50.00A/AUTO MODE

Pagina 44

KEW6315 Items measured at Instantaneous measurement KEW6315 - 136 - Active power P [W] Range Current Voltage 8128 8127 8126 50.00A 5000mA 10

Pagina 45

Items to be calculated KEW6315 - 137 - KEW6315 Items to be calculated Apparent power S [VA] Range Same as active power. Displayed digit Same

Pagina 46 - Sensor detection

KEW6315 KEW6315 - 12 WaveformWaveformsgraph. See “6.5 WaveformHarmonic AnalysisHarmonic components of volt

Pagina 47

KEW6315 Items to be calculated KEW6315 - 138 - Power factor: PF Display range -1.000 to 0.000 to 1.000 Accuracy ±1dgt against each calculated

Pagina 48 - CAUTION:

Items to be calculated KEW6315 - 139 - KEW6315 Current unbalance ratio Aunb [%] Displayed digit 5-digit Display range 0.00% to100.00% Wiri

Pagina 49 - 5 Settings

KEW6315 Items measured at Integration measurement KEW6315 - 140 - Items measured at Integration measurement Power consumption (if P>0) Active

Pagina 50 - 5.2 Basic setting

Items measured at Integration measurement KEW6315 - 141 - KEW6315 Reactive power energy +WQ [Varh] Displayed digit 6-digit, Unit: m, k, M, G,

Pagina 51

KEW6315 Items measured at Integration measurement KEW6315 - 142 - Apparent power energy -WS[VAh] Displayed digit 6-digit, Unit: m, k, M, G, T (

Pagina 52 - Wiring diagrams

Items measured at Demand measurement KEW6315 - 143 - KEW6315 Items measured at Demand measurement Target value (DEMTarget) Displayed digit 4-

Pagina 53 - Wiring connection

KEW6315 Items measured at Harmonics measurement KEW6315 - 144 - Items measured at Harmonics measurement Meas. system : Digital PLL synchronizat

Pagina 54

Items measured at Harmonics measurement KEW6315 - 145 - KEW6315 R.m.s. harmonics current Ak [Arms] Range Same as r.m.s. current Displayed d

Pagina 55 - ”VT Ratio”

KEW6315 Items measured at Harmonics measurement KEW6315 - 146 - Harmonics reactive power Qk [var] (used for internal calculation only) Equation

Pagina 56 - CAUTION

Items measured at Harmonics measurement KEW6315 - 147 - KEW6315 Harmonics voltage total distortion factor THDVR [%] Displayed digit 4-digit D

Pagina 57 - Default values

1.2 Features KEW6315 - 13 - KEW6315 1.2 Features This is a Clamp-type Power Quality Analyzer that can be used for various wiring systems. It

Pagina 58

KEW6315 Items measured at Harmonics measurement KEW6315 - 148 - Total harmonics current phase angle θAk [deg] Displayed digit 4-digit Display

Pagina 59 - ”CT Ratio”

Items measured at Power quality measurement KEW6315 - 149 - KEW6315 Items measured at Power quality measurement Voltage transient Meas. system

Pagina 60

KEW6315 Items measured at Power quality measurement KEW6315 - 150 - Inrush current Range Same as r.m.s. current Displayed digit Same as r.m.s.

Pagina 61

Items measured at Power quality measurement KEW6315 - 151 - KEW6315 Flicker Displayed items Time left: V: Pst(1min): Pst: Plt: Max Pst: Max Pl

Pagina 62

KEW6315 10.4 Specification of Clamp sensor KEW6315 - 152 - 10.4 Specification of Clamp sensor <MODEL8128 > <MODEL8127 > <MODE

Pagina 63 - ”Inspection cycle”

10.4 Specification of Clamp sensor KEW6315 - 153 - KEW6315 <MODEL8125 > <MODEL8124 > Rated current AC 500Arms (707Apeak)

Pagina 64

KEW6315 10.4 Specification of Clamp sensor KEW6315 - 154 - <KEW8129 > <KEW8130 > 300A Range: AC 300 Arms( 424Apeak) 1000A R

Pagina 65 - ”MAX hold”

10.4 Specification of Clamp sensor KEW6315 - 155 - KEW6315 <MODEL8141 > <MODEL8142 > <MODEL8143 > Rated current

Pagina 66

KEW6315 10.4 Specification of Clamp sensor KEW6315 - 156 - <KEW8146 > <KEW8147 > <KEW8148 > AC 30Arms (42.4Apeak) AC

Pagina 67

11.1 General troubleshooting KEW6315 - 157 - KEW6315 11. Troubleshooting 11.1 General troubleshooting When defect or breakdown of the instrume

Pagina 68

KEW6315 KEW6315 - 14 1.3 Constructional drawing Size AA alkaline dry-cell battery (LR6) or Size AA Ni-MH rechargea

Pagina 69

KEW6315 11.2 Error messages and actions KEW6315 - 158 - Symptom Check Data cannot be saved on the SD card.  SD card is inserted correctly? 

Pagina 70

11.2 Error messages and actions KEW6315 - 159 - KEW6315 the instrument or the sensor. Message Detail & Action Battery level is low. Powe

Pagina 71

KEW6315 11.2 Error messages and actions KEW6315 - 160 - Message Detail & Action New sensor is detected. Recheck the basic setting for SET

Pagina 72

05-12 92-2161 DISTORIBUTOR Kyoritsu reserves the rights to change specifications or designs described in this manual without

Pagina 73

1.4 Steps for measurement KEW6315 - 15 - KEW6315 1.4 Steps for measurement Read through the operating instructions described in “Safety wa

Pagina 74

KEW6315 2.1 Display (LCD)/ Keys KEW6315 - 16 - Chap.2 Instrument layout 2.1 Display (LCD)/ Keys Display (LCD) Keys

Pagina 75 - Saved items

2.2 Connector KEW6315 - 17 - KEW6315 2.2 Connector Wiring configuration AC Voltage Input Terminal Current Input Terminal* Si

Pagina 77 - “Constant recording”

KEW6315 2.3 Side face KEW6315 - 18 - Analog input/ Digital output cover SD slot cover USB port USB port cover Analog input/ Digital output ter

Pagina 78 - Possible recording time

2.4 Voltage test lead and Clamp sensor KEW6315 - 19 - KEW6315 Barrier Barrier 2.4 Voltage test lead and Clamp sensor <Alligator clip>

Pagina 79

KEW6315 3.1 Key operation KEW6315 - 20 - 3 Basic operations 3.1 Key operation ENTER Key Confirm the entrie

Pagina 80 - “CH color”

3.2 Icons on the LCD KEW6315 - 21 - KEW6315 3.2 Icons on the LCD Icon Status KEW6315 is operating with battery. T

Pagina 81

KEW6315 3.3 Symbols on the LCD KEW6315 - 22 - 3.3 Symbols on the LCD *1 W screen: Displays of V and VL can be “customized” when “3P4W” is sel

Pagina 82 - “Power”

Inst/ Integration/ Demand -3.5 Screens Inst/ Integration/ Demand Switching screens Press the key to toggle the screens.

Pagina 83 - “System reset”

KEW6315 KEW6315 - 24 Vector Switching screens Waveform Switching screens Wiring diagram Diagram of the selected wi

Pagina 84

Harmonics -Harmonics Switching screens CurrentLogarithm List, Rate of content Phase angleCurrentVoltage, Linear, Overa

Pagina 85 - “Internal”/ “SD card”

KEW6315 KEW6315 - 26 Power quality Switching displayed items Settings Switching displayed items Event

Pagina 86 - “Space”

Putting Input terminal plate on the Input terminal KEW6315 - 27 - KEW6315 4 Getting started 4.1 Preparation Putting Input terminal plate on

Pagina 87 - “SD card”

Contents KEW6315 - 1 - KEW6315 Contents ·································································································· 1 U

Pagina 88

KEW6315 Attaching Markers to Voltage test leads and Clamp sensors KEW6315 - 28 - Attaching Markers to Voltage test leads and Clamp sensors Atta

Pagina 89 - “KEW6315 Setting”

Battery KEW6315 - 29 - KEW6315 4.2 Power Supply Battery KEW6315 operates with either an AC power supply or batteries. Capable of performing

Pagina 90 - “Power quality data”

KEW6315 Battery Mark on the LCD/ Battery level KEW6315 - 30 - Battery Mark on the LCD/ Battery level Power supply icon changes as follows, and t

Pagina 91

How to install batteries KEW6315 - 31 - KEW6315 How to install batteries: Follow the steps below and install batteries. 1 Disco

Pagina 92

KEW6315 KEW6315 - 32 Follow the procedure below, and connect the Power cord. 1 Confirm that the instrument is powered off. 2 Connect the Pow

Pagina 93 - “Read settings”

4.3 Placing / removing SD card KEW6315 - 33 - KEW6315 4.3 Placing / removing SD card Check the following points before using SD card. CAUT

Pagina 94 - Chap. 6 Displayed Items

KEW6315 Inserting SD card KEW6315 - 34 - Inserting SD card: 1 Open the Connector cover. 2 Insert the SD card into the SD card slot w

Pagina 95

4.4 Voltage test leads and Clamp sensor connection KEW6315 - 35 - KEW6315 4.4 Voltage test leads and Clamp sensor connection Check the follow

Pagina 96

KEW6315 KEW6315 - 36 4.5 Start KEW6315 Start-up Screen Hold down the POWER key until the following screen is displayed on the LCD. To power off t

Pagina 97

Start of recording -4.6 Recording procedures Start of recording Press the Key. Choose either “Quick start guide” or “Start now” to st

Pagina 98 - ”Displayed items”

KEW6315 Contents KEW6315 - 2 - 4.2 Power Supply ············································································· 29  Battery ···

Pagina 99 - Displaying Trend graph

KEW6315 End of recording KEW6315 - 38 - End of recording Press the Key. Check the information about recording, or stop the record

Pagina 100 - “List display”

Start measurement with “Quick start guide” -Start measurement with “Quick start guide” Select the recording it

Pagina 101

KEW6315 KEW6315 - 40 Select the rec. interval Select the rec. method(6) Select a recording interval.* Selecting case

Pagina 102 - 6.2 Integration value “Wh”

Start measurement with “Quick start guide” KEW6315 - 41 - KEW6315 Orientation of Clamp sensor Power source Arrow mark: Point towards load sid

Pagina 103 - ”Demand”

KEW6315 KEW6315 - 42 (4)(5) Test Environment Check Switching screens Select and press the “ENTER” on “OK”/ ”NG” to se

Pagina 104 - Instantaneous value “W”

Start measurement with “Quick start guide” -NG judgment Wiring check Close the result display. Then, the blinking vectors and the values of NG item

Pagina 105 - Shifts in specific period

KEW6315 KEW6315 - 44Self-diagnosis If “NG” judgment is given frequently, there might be something wrong with the instrument. instrument and refer t

Pagina 106 - Demand change

Start measurement with “Quick start guide” -(8)(9) Setting for recording method The following explains how to set recording start date and time. (8

Pagina 107 - 6.4 Vector

KEW6315 KEW6315 - 46 Switching of displayed parameters Basically, the Cursor Key is used for selecting an item, the selection, a

Pagina 108 - ”Check”

List of setting items KEW6315 - 47 - KEW6315 5 Settings 5.1 List of setting items Settings for measurement condition and data saving are n

Pagina 109 - 6.5 Waveform

Contents KEW6315 - 3 - KEW6315  Filter setting for Flicker measurement ········································· 69  Target power factor f

Pagina 110 - 6.6 Harmonics

KEW6315 Basic setting KEW6315 - 48 - 5.2 Basic setting Press the Key. Use the Key to display the Bas

Pagina 111 - order

Settings of wiring system KEW6315 - 49 - KEW6315 Settings of wiring system ”Basic wiring” Choose one according to the wiring system to

Pagina 112

KEW6315 Settings of wiring system KEW6315 - 50 - Wiring diagrams When the blue highlight is located at “Wiring”, you can check the wiring diagra

Pagina 113 - “V/A/P/ΣP”

Wiring connection KEW6315 - 51 - KEW6315 Wiring connection Read the following precautions prior to wiring connection. DANGER  With attentio

Pagina 114

KEW6315 Wiring connection KEW6315 - 52 - Clamp sensor direction for correct measurement:  Confirm that the wiring system selected with the in

Pagina 115 - “V”/”A”/”P/ΣP”

Settings of voltage measurement KEW6315 - 53 - KEW6315 Settings of voltage measurement “Voltage range” Choose a desired voltage ra

Pagina 116 - 6.7 Power quality

KEW6315 VT/ CT KEW6315 - 54 - VT/CT* * This setting belongs to Current measurement setting. DANGER  With attention to the measurement categor

Pagina 117

Settings of voltage measurement KEW6315 - 55 - KEW6315 ”Nominal voltage” Set the nominal voltage values applied from the measured object. Sele

Pagina 118 - Displaying recorded events

KEW6315 Settings of current measurement KEW6315 - 56 - Settings of current measurement “Clamp” : Clamp sensors for current measurement

Pagina 119

Settings of voltage measurement KEW6315 - 57 - KEW6315 ”Current range” Choose a desired current range. While “Record” is set at the “Recording

Pagina 120

KEW6315 Contents KEW6315 - 4 - 6.7 Power quality ············································································· 114  Factors i

Pagina 121 - ”Event detection”

KEW6315 Settings of External input terminal/ reference frequency KEW6315 - 58 - Settings of External input terminal/ reference frequency

Pagina 122 - ”Event”

5.3 Measurement setting KEW6315 - 59 - KEW6315 5.3 Measurement setting Press the Key. Change the tabs to “Measurement”. Sett

Pagina 123

KEW6315 Settings of demand measurement KEW6315 - 60 - ”Target value” Set the demand target value. Selection 0.001mW - 999.9TW(100.0kW) * Default

Pagina 124 - Displaying changes of Plt

Settings of demand measurement KEW6315 - 61 - KEW6315 ”Inspection cycle” The buzzer sounds when the predicted value exceeds the target value w

Pagina 125 - Chap. 7 Other functions

KEW6315 Outline of demand measurement concept KEW6315 - 62 - Outline of demand measurement concept In such a contract the electricity tariff ra

Pagina 126

Settings for Harmonic analysis KEW6315 - 63 - KEW6315 Settings for Harmonic analysis “THD calculation” THD stands for ”Total Harm

Pagina 127 - Chap. 8 Device connection

KEW6315 Settings for Harmonic analysis KEW6315 - 64 - ”Edit allowable range” Set the EMC allowable range (rate of content) for harmonics per ord

Pagina 128 - 8.3 Signal control

Threshold setting for Power quality (Event) KEW6315 - 65 - KEW6315 Threshold setting for Power quality (Event) Press the (OFF/ O

Pagina 129 - ”Output terminal”

KEW6315 Threshold setting for Power quality (Event) KEW6315 - 66 - “Transient”: Over-voltage (Impulse) Set an instantaneous voltage value as a t

Pagina 130

Threshold setting for Power quality (Event) KEW6315 - 67 - KEW6315 “SWELL”: Instantaneous voltage rise Set the threshold value (rms voltage in

Pagina 131

Unpacking Procedure KEW6315 - 5 - KEW6315 Unpacking procedure We thank you for purchasing our Power Quality Analyzer “KEW6315”. P

Pagina 132 - Chap. 10 Specification

KEW6315 Threshold setting for Power quality (Event) KEW6315 - 68 - “DIP”: Instantaneous voltage drop Set the threshold value (rms voltage in one

Pagina 133 - *ref. value at 23ºC

Filter setting for Flicker measurement KEW6315 - 69 - KEW6315 Filter setting for Flicker measurement “Filter coefficient” Set a prope

Pagina 134

KEW6315 Target power factor for Capacitance calculation KEW6315 - 70 - Target power factor for Capacitance calculation “Target power fa

Pagina 135

5.4 Recording setting KEW6315 - 71 - KEW6315 5.4 Recording setting Press the Key. Change the tabs to “Recording”.

Pagina 136 - R.M.S. Voltage V [Vrms]

KEW6315 Settings for recording items KEW6315 - 72 - Settings for recording items The possible recording time on SD cards or the internal

Pagina 137 - R.M.S. Current A [Arms]

Saved items KEW6315 - 73 - KEW6315 Saved items The following data measured on each CH will be saved according to the selected recording method

Pagina 138 - Active power P [W]

KEW6315 Recording method KEW6315 - 74 - Recording method “Interval” Set the interval to record the measured data on the SD or internal me

Pagina 139 - PSsign −

Recording method KEW6315 - 75 - KEW6315 “Start” Select the method to start recording. Selection Manual/ Constant rec./ Time period rec. * Defa

Pagina 140 - ( ){ } ( ){ }

KEW6315 Possible recording time KEW6315 - 76 - “Time period recording” Measured data will be recorded at the preset interval for the specified

Pagina 141 - Capacitance calculation

5.5 Other settings KEW6315 - 77 - KEW6315 5.5 Other settings Press the Key. Change the tabs to “Others”. Settings for system

Pagina 142

KEW6315 Unpacking Procedure KEW6315 - 6 - 1. Main unit 2. Voltage test lead 3. Power cord 4.USB cord 5. Quick manual 6.CD-ROM 7. Bat

Pagina 143 - Active power energy - WP[Wh]

KEW6315 Settings for system environment KEW6315 - 78 - “Date format” Select a desired date display format. The selected date format will be refl

Pagina 144 - Duration of integration

KEW6315 Setting KEW6315 - 79 - KEW6315 KEW6315 Setting “Time” Adjust and set the internal system clock. Selection dd/ mm/ yyyy hh:

Pagina 145 - +WPsum (+WSsum)

KEW6315 KEW6315 Setting KEW6315 - 80 - “Buzzer” Keypad sounds can be muted. The warning buzzer for demand judgment or low battery voltage sounds

Pagina 146 -

KEW6315 Setting KEW6315 - 81 - KEW6315 “Backlight” This setting can turn off the backlight automatically when the prescribed time passes after

Pagina 147 - Harmonics power Pk [W]

KEW6315 5.6 Saved data KEW6315 - 82 - 5.6 Saved data Press the Key. Change the tabs to “Saved data”. Save the “ ”: Measurement dat

Pagina 148

To delete, transfer or format the recorded data KEW6315 - 83 - KEW6315 “Delete data” Show the list of the recorded data, and then select unnec

Pagina 149

KEW6315 To delete, transfer or format the recorded data KEW6315 - 84 - “Space” Storage media information can be checked with the Key. Press t

Pagina 150

To delete, transfer or format the recorded data KEW6315 - 85 - KEW6315 “Transfer data” Select the data you want to transfer from the “ ”: inte

Pagina 151 - Voltage swell, Dip, INT

KEW6315 To delete, transfer or format the recorded data KEW6315 86 “BACK” To return to the “Saved data” screen, press the Key. “Format” Fo

Pagina 152 - Inrush current

Type of the saved data KEW6315 - 87 - KEW6315 Type of the saved data Data file handling The file name will be assigned automatically. File

Pagina 153 - Flicker

Unpacking Procedure KEW6315 - 7 - KEW6315 12. Clamp sensor (depending on model purchased) 13. Instruction manual for Clamp sensor 14.

Pagina 154 - Jaws – Output terminal

KEW6315 Type of the saved data KEW6315 - 88 - “Data folder” New folder will be created per measurement to save the interval and power quality da

Pagina 155

KEW6315 settings and Data loading KEW6315 - 89 - KEW6315 KEW6315 settings and Data loading Select a desired operation. Confirm. “S

Pagina 156

KEW6315 KEW6315 settings and Data loading KEW6315 - 90 - “Space” Storage media information can be checked with the Key. Press the Key to c

Pagina 157

KEW6315 settings and Data loading KEW6315 91 KEW6315 “Read settings” Read the “ ”: Setting data from the “ ”: SD card or from the “ ”: interna

Pagina 158

KEW6315 Instantaneous value “W” KEW6315 - 92 - Chap. 6 Displayed Items 6.1 Instantaneous value “W” Press the Key. Display the screen for

Pagina 159 - Troubleshooting

List display of the measured values KEW6315 - 93 - KEW6315 *1 W screen: Displays of V and VL can be “customized” when “3P4W” is selected. *2

Pagina 160

KEW6315 List display of the measured values KEW6315 - 94 - “Switching the displayed systems” Press the key and switch the displayed systems.

Pagina 161

List display of the measured values KEW6315 - 95 - KEW6315 3P3W3A (Three-phase 3-wire) 3P4W (Three-phase 4-wire) “Switching the

Pagina 162 - See “To delete, transfer or

KEW6315 Zoom display KEW6315 - 96 - Zoom display Example: 8-split screen Select 4 or 8 values and display the values on one screen.

Pagina 163 - www.kew-ltd.co.jp

Displaying Trend graph KEW6315 - 97 - KEW6315 ”Type of value” Any of the following values can be displayed in each column. Inst: Instantaneo

Comentarios a estos manuales

Sin comentarios